Home | About Us | News | Programs & Activities | Library | Water Operations | Site Index
 CVP - Folsom and Sly Park Units 
 Engineering Data

CVP - Folsom and Sly Park Units  -  Main Page

Facilities in Operation

Storage Dams

3      

Diversion Dams

1      

Tunnels

0.97 mi  

Conduits

53.5 mi  

Powerplants

2      

Transmission Lines

2.15 mi  

Substations

2      


Storage Facilities

Diversion Facilities

Carriage Facilities

Camino Conduit

Location

From Sly Park Dam generally west to Camino, California.

Construction period

1953-1955  

Length

38,016 ft  

Capacity

125 cfs  

Cross section:

Horseshoe

   Description:

Precast concrete and welded plate steel

   Diameter

4-3 ft  


Camino Tunnel

Location

At County Road No. 90 about 1.5 mi east of Sly Park Dam

Construction period

1954-1955  

Length

2,289 ft  

Capacity

125 cfs  

Cross section:

Horseshoe

   Description:

Steel reinforced, concrete lined

   Diameter

7 ft  

   Lining thickness

3.5-7 in  


Camp Creek Tunnel

Location

From Camp Creek Diversion Dam generally northwest to Sly Park Reservoir.

Construction period

1952-1953  

Length

2,845 ft  

Capacity

500 cfs  

Cross section:

Horseshoe

   Description:

Steel reinforced, concrete lined

   Diameter

7 ft  

   Lining thickness

3.5-7 in  


El Dorado Main

Location

From Reservoir No. 1 generally west and terminating 3 miles west of Placerville.

Construction period

1962-1963  

Length

95,503 ft  

Capacity

440 cfs  

Cross section:

Circular

   Description:

Steel pipe

   Diameter

12-33 in  


El Dorado Main No. 2

Location

From Reservoir 2A generally west and terminating 5 miles west of Placerville,California.

Construction period

1977-1978  

Length

73,196 ft  

Capacity

20-61 cfs  

Cross section:

Circular

   Description:

Steel pipe

   Diameter

18-33 in  


Pleasant Oak Main

Location

From Reservoir A generally west and terminating south of Placerville, California.

Construction period

1975-1977  

Length

75,599 ft  

Capacity

6.1-37.4 cfs  

Cross section:

Circular

Description:

Pretensioned concrete and reinforced plastic mortar pipe

Diameter

15-30 in  


Power Facilities

 

 